Tomzn Tovpd1-60-ec Manual ((free)) <Free Forever>

Snap the device onto a standard 35mm DIN rail inside your distribution box or consumer unit. Wiring Configuration

UPS systems and battery chargers are often sensitive to both over‑voltage and under‑voltage. The TOVPD1‑60‑EC prevents these devices from operating outside their safe input range.

Terminal connections (typical):

In factories and workshops, the relay can be used to protect motor control circuits, HVAC systems, and automation panels. The over‑current function adds an extra layer of protection against overloads. tomzn tovpd1-60-ec manual

: Indicates an over-voltage or under-voltage protection event is active. A LED Flashing : Indicates an over-current protection event is active. Manual Adjustment Disable Over-Voltage Protection : Press the button when reaching 300V. Disable Under-Voltage Protection : Press the button when reaching 150V. Restore Factory Settings : Press and hold the button for more than 12 seconds. Fault Inquiry : Press and hold the

The TOVPD1-60-EC features a standard 35mm DIN rail clip. To mount:

Understanding the technical boundaries of your device ensures safe operation and prevents premature hardware failure. Specification TOVPD1-60-EC Rated Voltage 230V AC (50Hz / 60Hz) Rated Current Range 1A to 60A (Adjustable, Default: 40A) Over-voltage Protection Value Range 230V to 300V (Adjustable, Default: 270V) Under-voltage Protection Value Range 140V to 210V (Adjustable, Default: 170V) Power Consumption Electrical Machinery Life > 100,000 Cycles Installation 35mm DIN Rail Wiring and Installation Diagram Snap the device onto a standard 35mm DIN

Once voltage or current returns to safe, preset parameters, the internal countdown timer activates. When the countdown reaches zero, the relay automatically closes, restoring power to the circuit. Troubleshooting Guide Potential Cause No input power or wrong wiring.

Automatically restores power once the line voltage and current return to the preset safe range.

Follow these steps to program individual protection thresholds and delay timers. A LED Flashing : Indicates an over-current protection

Connect the hot wire feeding your consumer unit or appliances to the terminal marked OUT L . Connect the load neutral wire to the terminal marked OUT N .

Snap the TOVPD1-60-EC onto a standard 35mm DIN rail inside your distribution box.

When a generator is running, it may experience voltage dips under heavy load. The TOVPD1‑60‑EC can disconnect non‑essential loads during low voltage, allowing the generator to recover.

Press & Hold SET (3s) ➔ Select Parameter ➔ Adjust Value (▲/▼) ➔ Press SET to Save/Next 1. Over-Voltage Protection Value Press and hold for 3 seconds until the screen flashes.

and need to know the best values for your appliances?