Before installing your Shinko servo drive, ensure the environment meets the technical specifications outlined in the official Shinko Technos documentation . Environmental Requirements 0 to 50°C (32 to 122°F) without icing. Humidity: 35 to 85% RH (non-condensing). Atmosphere: Minimum dust, no corrosive or flammable gases. Vibration: No mechanical vibrations or shocks. Safety Warnings
Supplies variable frequency and voltage to the servo motor.
The system configuration may vary depending on the specific application and requirements.
Supports up to 2MHz for high-precision pulse positioning control.
Install the driver in an environment free from conductive dust, corrosive gases, or excessive moisture. shinko servo drive manual
Access the drive parameters via the integrated 5-digit LED keypad or PC-based commissioning software. Key Operational Parameter List Parameter Code Description Default Value Recommended Setting / Range Control Mode Selection 0: Position, 1: Speed, 2: Torque P1-02 Proportional Position Gain ( Kpcap K sub p 30 to 80 Hz (Adjust for rigidity) P1-04 Proportional Speed Gain ( Kvcap K sub v 80 to 250 Hz (Varies by inertia) P1-05 Speed Integral Time Constant ( Ticap T sub i 10 to 50 ms (Eliminates steady-state error) P2-08 Electronic Gear Ratio (Numerator) 1 to 65535 (Matches pulse units to physical distance) P2-09 Electronic Gear Ratio (Denominator) 1 to 65535 Autotuning Procedure
Use twisted-pair, braided shield wiring for both the CN1 I/O control signals and the CN2 encoder cable. Terminate the shield braid 360 degrees around the connector metallic shell rather than pigtailing it to a ground pin. 3. Control Mode Architecture
: Drivers should be installed in a control panel with ambient temperatures kept below 50°C to ensure the longevity of electronic parts like electrolytic capacitors.
Are you currently encountering a specific on the display? Before installing your Shinko servo drive, ensure the
The drive regulates output current rather than motor speed, matching an analog voltage reference to a target torque output. 4. Key Parameter Configurations for Setup
Indicates phases and voltage limits (e.g., A for Single-Phase 220V, B for Three-Phase 220V, C for Three-Phase 380V–440V).
Most Shinko drives use a high-density DB44 or similar connector for I/O. Key pins usually include:
Mechanical stress and incorrect mounting directly degrade the performance of high-speed servo drives. Follow these standardized panel guidelines during physical deployment. Atmosphere: Minimum dust, no corrosive or flammable gases
The drive regulates current output directly to control motor shaft torque rather than monitoring speed or position. This is ideal for tension control applications, winders, or pressing mechanisms. It requires a hardcoded speed limit parameter to prevent motor runaway conditions if resistance drops to zero. 4. Key Parameters and Configuration Steps
Install inside an IP54-rated electrical cabinet to protect against airborne contaminants, oil mist, and moisture. Environmental Limits Operating Limit Ambient Temperature 0°C to +55°C (Derate output above 45°C) Humidity 90% RH or less (Non-condensing) Vibration Resistance Max 4.9 m/s² (0.5G) at 10 to 60 Hz Altitude Below 1,000 meters above sea level 3. Wiring and Terminal Connections
Shinko drives are configured via a handheld keypad or PC software (often called "V-Support Software").